Used in the DDC
to read all the temperature probes.
Advantech Computer
Part #25262
DDC Computer
loaded with DDC software, floppy drive cables, and video card.
(Does not include data acquisition card).
Air Solenoid - 2 Way
Part #65697
1/8" NPT, 115
volt AC. 2-way - NC
Air Solenoid - 3 Way
Part #65698
1/8" NPT, 115
VAC.
Air Supply Regulator with Gauge
Part #66306
Maintains high
air flow with steady pressure control with minimal pressure
drop. Fluctuations in secondary pressures are minimal,
regardless of fluctuations in primary pressures. Secondary
pressure range: 5 to 125 PSIG. NPT size: 1/4".
Alarm Horn
Part #30975
Warning device
for flame failure, duration of process cycle, etc., 120 VAC.
Alarm Horn
Part #30080
Warning device
for: flame failure, duration of processing cycle, set point
changes, time for internal temperature check, etc., 120VAC, 125
AMP., 50/60 Hz.
Board
Part #25220
Board PC to I/O
mounting rack, G4AC50PT022. For use in DDC standard system.
Board
Part #25197
Board DT2815,
data acquisition. For use in DDC standard system.
Board
Part #25225
Board A108-P,
MLC-AD12-8P. For use in DDC standard system.
Board, Pentium
Part #25306
Pentium
Motherboard, PCA-61541 for use in all DDC systems: standard,
modicon, and windows
Button
Part #31676
E-Stop button,
illuminated
Calibration Resistor
Part #70594
Calibrate DDC
Modicon to 230 F.
Calibration Resistor
Part #70595
Calibrate DDC
Modicon to 100 F.
Card
Part #25246
Card SVGA 1078 x
768 Advantech PCA-6141. For use in DDC standard system.
Circular Chart Recorder Ink
Part #25082
For use with
Bristol Recorder (2.5 oz bottle)
Red Ink (1 bottle)
Note: Please specify ink number.
Circular Chart Recorders Ink
Part #25051
For use with
Bristol Recorder (2.5 oz bottle)
Blue Ink (1 bottle)
Circular Recorder Charts
Part #25120
Honeywell :
Packed 100 charts per box. All charts 24 hour.
Range 0 - 200 F
11-1/2" diameter chart
Note: For Drying Room charts please specify chart number
Circular Recorder Charts
Part #25139
Honeywell:
Packed 100 charts per box. All charts 24 hour.
Range 0 - 200 F
For microprocessors, 10-1/2" diameter chart
Note: For Drying Room charts please specify chart number
Circular Recorder Charts
Part #25156
Partlow: Packed
100 charts per box. All charts 24 hour. Range: 30 - 230 F
Note: For Drying Room charts please specify chart number
Circular Recorder Charts
Part #25162
Bristol: Packed
100 charts per box. All charts 24 hour.
Range: 60 - 180 F
Note: For Drying Room charts please specify chart
Circular Recorder Charts
Part #25155
Bristol: Packed
100 charts per box. All charts 24 hour.
Range: 0 - 400 F
Note: For Drying Room charts please specify chart
Circular Recorder Charts
Part #25136
Honeywell:
Packed 100 charts per box. All charts 24 hour.
Range 50 - 250 F
Circular Recorder Charts
Part #25032
Partlow: Packed
100 charts per box. All charts 24 hour.
Range: 50 - 250 F
Note: For Drying Room charts please specify chart number
Circular Recorder Charts
Part #25291
Honeywell:
Packed 100 charts per box. All charts 24 hour.
Range 0 - 150 C
Note: For Drying Room charts please specify chart number
Circular Recorder Charts
Part #25075
Bristol: Packed
100 charts per box. All charts 24 hour.
Range: 40 - 240 F
Note: For Drying Room charts please specify chart
Circular Recorder Charts
Part #25031
Partlow: Packed
100 charts per box. All charts 24 hour.
Range: 0 - 350 F
Note: For Drying Room charts please specify chart number
Connector - Block - #UMS
Part #31345
For use in Alkar
DDC control panels
Connector - Plug - #MVST
Part #31346
For use in Alkar
DDC control panel
Contact Blocks
Part #30551
Contact blocks
for electrical, and stop/start push-button switches. 10 AMP.,
600 Volt.
Normally closed
Contact Blocks
Part #30550
Contact blocks
for electrical and stop/start push-button switches. 10 AMP., 600
Volt.
Normally open
Controller
Part #25300
Microprocessor
LFP-100
Controller
Part #25266
DC2030B-EE-20-11-0A00000-00-0
Cooler, Vortex
Part #31184
Air cooler for
use in DDC Modicon.
Corrosion Inhibitor
Part #30910
Used for control
of corrosion in instrumentation controls.
Delay Start Timer
Part #30082
Used for special
application only. Delay start of Wet Bulb set point or preset
time (in seconds) allowing Dry Bulb to reach set point first.
115 VAC, 10 AMP rated.
Desiccant Dehydrator Dryer Unit
Part #65093
A manual
compressed air dryer unit, that indicates replacement of
regeneration of desiccant crystals by changing from blue to pink
within the transparent bowl window. Dryer unit includes two (2)
bags of desiccant. Additional bags of desiccant may be ordered.
Desiccant Bowl Specifications
Capacity: 1.74 pounds
Temperature rating: up to 125 F
Pressure rating: up to 150 PSIG
Dryer Specifications
Dries up to 4400 standard cubic feet at 70 F (saturated inlet
air temperature) at 100 PSIG
Dessicant Crystals
Part #65094
Replacement
dessicant crystals for Dessicant Dehydrator Dryer Unit. Two bags
are required. Price is per bag.
Digital I/O Board
Part #25216
For use with the
plug-in modules to control the DCC input/output. (Pre Modicon)
Door Interlock
Part #30863
Instrument panel
interlock switch. Used for all instrument control panels.
Dry Bulb Controller Part #25095
Three mode (for
Steam Heated Ovens only). This part is OBSOLETE.
Dry Bulb and Wet Bulb Sensor
Part #25127
20 ft RTD Dry
Bulb and Wet Bulb Sensor.
Electrical Switch
Part #30894
2-Position with
contact block.
Electrical Switch
Part #30897
3-Position with
contact block.
Fan Cord
Part #31181
Use with biscuit
fan part no. 31179.
Fan, Biscuit
Part #31179
For DDC panels.
Finger Guard
Part #31180
Use with biscuit
fan part no. 31179.
Floppy Drive 3.5
Part #25245
For use in Alkar
DDC and WonderWare controls.
Hard Drive
Part #25263
20 gb hard drive
for use in DDC and WonderWare controls.
Honeywell Chart Recorders
Part #25236
A
self-contained, enclosed, temperature recording chart unit.
Electrically operated (115 VAC, 1ph, 60 Hz.)
24 Hour military time print (15 min. intervals) circular chart
Facilities for locking/sealing the chart
Replaces AR100 Series
Model DR4200 is available in a one-pen or two-pen version. This
recorder includes a self-test feature that checks the
operational status of Major Functions.
2-Pen recorder/controller. Used for back-up control on
microprocessor control panels (DR4200 EV2)
Honeywell Chart Recorders
Part #25128
A
self-contained, enclosed, temperature recording chart unit.
Electrically operated (115 VAC, 1ph, 60 Hz.)
24 Hour military time print (15 min. intervals) circular chart
Facilities for locking/sealing the chart
Replaces AR100 Series
Model DR4300 is available in a one-pen or two-pen version. This
recorder includes a self-test feature that checks the
operational status of Major Functions.
2-Pen recorder (DR4312)
Honeywell Chart Recorders
Part #25141
A
self-contained, enclosed, temperature recording chart unit.
Electrically operated (115 VAC, 1ph, 60 Hz.)
24 Hour military time print (15 min. intervals) circular
chart
Facilities for locking/sealing the chart
Replaces AR100 Series. Model DR4300 is available in a
one-pen or two-pen version. This recorder includes a
self-test feature that checks the operational status of
Major Functions.
1-Pen recorder (DR4311)
Note: Please specify recorder part number.
Honeywell Chart Recorders
Part #25171
A
self-contained, enclosed, temperature recording chart unit.
Electrically operated (115 VAC, 1ph, 60 Hz.)
24 Hour military time print (15 min. intervals) circular chart
Facilities for locking/sealing the chart
Replaces AR100 Series
Model DR4200 is available in a one-pen or two-pen version. This
recorder includes a self-test feature that checks the
operational status of Major Functions.
1-Pen recorder/controller. Used for iternal temperature control
on standard panel, back-up control on microprocessor control
panels (DR4200 EVI)
Indicating Bulb
Part #30871
Replacement in
control panel.
Bayonet socket - 4 watt, 120VAC
Indicating Bulb
Part #30252
Replacement in
control panel.
Screw socket - 6 watt, 120VAC
Indicating Light Socket Assembly
Part #30895
Complete with
twist type socket and indicator bulb. 4 Watt, 120 VAC. Lense
color: green.
Green lense
Indicating Light Socket Assembly
Part #30893
Complete with
twist type socket and indicator bulb. 4 Watt, 120 VAC. Lense
color: red.
Red lense
Internal Control Regulator Control Panel
Part #30898
0-30 psi. 1/4"
NPT
Internal Temperature Controls
Part #25238
DC230L-E0-00-10
Used for internal temperature alarm or limit
Internal Temperature Controls
Part #25237
DC230B-EE-00-10
Used on Standard and Jumo control panels for wet and dry bulb
controllers.
Internal Temperature Probe
Part #25163
RTD Probe to
monitor internal temperature of product. 3 wire, 25 ft long
lead.
Internal Temperature Probe
Part #25121
Probe to monitor
internal temperature of product (type J).
25 foot
Internal Temperature Probe
Part #25288
RTD Probe to
monitor internal temperature of product. 3 wire, 32 ft long
lead.
Internal Temperature Probe
Part #25293
To measure
internal temperature of hot dogs.
Internal Temperature Probe
Part #25142
Probe to monitor
internal temperature of product (type J).
12 foot
Junction Box Enclosure
Part #31755
8" x 10", 3 pen
and 4 pen
Junction Box Enclosure
Part #31756
10" x 12"
Junction Box Enclosure
Part #31693
6" x 6", 1 pen
and 2 pen
Junction Box Enclosure, 10
Part #45072
Obsolete.
Replaced by part # 31756
Junction Box Enclosure, 6 Part #45052
Obsolete.
Replaced by part # 31693
Junction Box Enclosure, 8
Part #45074
Obsolete.
Replaced by part # 31755
Junction Box Internal Panel, 10
Part #45073
Junction Box Internal Panel, 6
Part #45053
Available in
1-pen and 2-pen.
Junction Box Internal Panel, 8
Part #45075
Available in
3-pen and 4-pen.
Junction Box Thermocouple Type J Wire
Part #30935
A special wire
(Iron-Constantan). Available for pens:
Pens
Quantity
1-Pen
100'
2-Pen
200'
3-Pen
300'
4-Pen
400'
Keypad
Part #31171
For use in Alkar
Modicon DDC.
Latch
Part #75335
Large knob
style, E3-10-505-50
Memory Module
Part #31542
For PLC based
controls.
Microalescer Replacement Filter, Type C
Part #66353
Replacement
filter only. (Coarse)
Microalescer Replacement Filter, Type D
Part #66352
Replacement
filter only.
(Fine) Old Type D
Microalescer Replacement Filter, Type D
Part #66430
Replacement
filter only.
(Fine) New Type D
Microalescer with Filter, Type C
Part #65100
Baffling system
for removing liquids (water & oil) and dirt particles
mechanically. Quick-disconnect clamp ring on metal bowl. Metal
bowl features level gauge and 11 oz. capacity. Comes with Type
"C" coarse, 0.01 micron filter. Replacement filters may be
ordered.
Microalescer with Filter, Type D
Part #66305
Baffling system
for removing liquids (water & oil) and dirt particles
mechanically. Quick-disconnect clamp ring on metal bowl. Metal
bowl features level gauge and 11 oz. capacity. Comes with Type
"D" fine, 0.003 micron filter. Replacement filters may be
ordered.
Bristol
Recorder. This part is now OBSOLETE and is no longer available.
A replacement part and kit is now available. See part number
91018 for this kit. Do not order part no. 25071.
Oven Temperature Chart Recorder Parts
Part #05206
Chart drive
motor for Honeywell chart recorders
Oven Temperature Chart Recorder Parts
Part #25074
Replacement
parts for the Oven Temperature Chart Recorder.
Pen Point Cleaning Wire (1)
Oven Temperature Chart Recorder Parts
Part #25073
Replacement
parts for the Bristol Oven Temperature Chart Recorder.
Chart Drive Motor
Oven Temperature Chart Recorder Parts
Part #25067
Replacement
parts for the Oven Temperature Chart Recorder. Replacement Pen
Arms, Short (Wet Bulb)
Oven Temperature Chart Recorder Parts
Part #25069
Replacement
parts for the Oven Temperature Chart Recorder.
Replacement Pen Points, Long (Dry Bulb)
Oven Temperature Chart Recorder Parts
Part #25068
Replacement
parts for the Oven Temperature Chart Recorder.
Replacement Pen Points, Short (Wet Bulb)
Oven Temperature Chart Recorder Parts
Part #25119
Replacement
parts for the Oven Temperature Chart Recorder.
Chart Holding Hub
Oven Temperature Chart Recorder Parts
Part #25066
Replacement
parts for the Oven Temperature Chart Recorder. Replacement Pen
Arms, Long (Dry Bulb)
Oven Temperature Chart Recorder Parts
Part #25108
Replacement
parts for the Oven Temperature Chart Recorder.
Door Handle/Latching Assembly
Panelmate Series 1000
Part #25277
The Panelmate
unit is a video control panel that will interface with a single
PLC or multiple PLCs on a network. The unit is a single piece
construction with front touchpanel and controls.
Partlow Replaceable Felt Tip Pens
Part #25157
Partlow Rec.
Controller:RED
Packaged 5 per pack.
Note: Please specify color number. For other internal
replacement parts, specify recorder type and part number or
section "D" for additional parts.
Partlow Replacement Pen Arms
Can be ordered
on request. Allow 4 weeks delivery. Long Arm.
Partlow Replacement Pen Arms
Can be ordered
on request. Allow 4 weeks delivery. Short Arm.
Pilot Light
Part #30257
Pilot light -
Green lens only
Pilot light
Part #30255
Pilot light -
Red lens only
Plug-In Modules
Part #25271
Modicon
expansion modules for DCC control panel. When ordering module,
refer to the number printed above wiring terminals.
Analog Output Card 202
Plug-In Modules
Part #25218
Used to control
the inputs/outputs for the DDC computer. Used on Advantech
computers (pre-1996)
AC Input Module - Yellow
Plug-In Modules
Part #25217
Used to control
the inputs/outputs for the DDC computer. Used on Advantech
computers (pre-1996)<
DC Output Module - Red
Plug-In Modules
Part #25219
Used to control
the inputs/outputs for the DDC computer. Used on Advantech
computers (pre-1996)<
AC Output Module - Black
Plug-In Modules
Part #25272
Modicon
expansion modules for DCC control panel. When ordering module,
refer to the number printed above wiring terminals.
A.C. Output Card 208
Plug-In Modules Part #25270
Modicon
expansion modules for DCC control panel. When ordering module,
refer to the number printed above wiring terminals.
RTD Input Card 204
Plug-In Time Delay Relay
Part #30881
Delay Start
Timer. Also, must order timer base #31653.
Plug-In Timer Base Only
Part #31653
Timer base for
use with Plug-In Time Delay Relay #30881.
Pneumatic Switch
Part #30233
For manual
control panels. Available for fresh air and exhaust damper
Pneumatic Switch
Part #30233
For manual
control panels. Available for smoke cook and steam cook switch.
Potentiometer
Part #31104
Potentiometer
P1004-13, 5 MEG OHMS
Potentiometer
Part #31213
Potentiometer,
SSAC Inc. VTP5N
Power Supply
Part #31539
For PLC based
controls.
Pressure Gauge
Part #25259
Liquid filled,
3-15 psi control output. For use in DDC, PLC, and WonderWare
controls.
Pressure Indication Gauge
Part #25118
2" Dial. 0-60
psi range.
Pressure Indication Gauge
Part #25003
2" Dial.
Available in 0-30 psi range.
Processor
Part #31543
For PLC based
controls.
Pushbutton
Part #30890
Pushbutton,
ABD110N-B
Pushbutton
Part #30891
Pushbutton, red
RTD Dry Bulb and Wet Bulb Probe
Part #25267
Measures Dry
Bulb and Wet Bulb temperature and sends signal back to
microprocessor.
Monel 400 Sheath
RTD Dry Bulb and Wet Bulb Probe
Part #25201
Measures Dry
Bulb and Wet Bulb temperature and sends signal back to
microprocessor.
Single element sensor
RTD Dry Bulb and Wet Bulb Probe
Part #25255
Measures Dry
Bulb and Wet Bulb temperature and sends signal back to
microprocessor. (15 ft)
Dual element sensor
Recorder Replacement Kit
Part #91018
This kit is a
replacement kit for Bristol Recorder part no. 25071 which is now
obsolete and is no longer available. Part no. 25128 along with
installation materials, junction box, probes, and filler plate
is a complete kit to replace part no. 25071. This new
replacement kit is ALKAR part no. 91018. Appropriate drawing
will be included in the kit. Field installation and wiring is
approximately 2 - 3 days.
Regulator
Part #30898
Internal control
regulator--control panel. 0-30 PSI. 1/4" NPT.
Relay
Part #30939
Relay RY4S-U-AC
120V IDEC
Relay
Part #31137
Relay, midget
power latching RH2LB120VAC
Relay
Part #31143
Relay, IDEC
RH1B-U 120VAC
Relay
Part #30225
8-Pin, Plug-in
style, D.P.D.T. contact arrangement. 115 VAC, 10 AMPS.
Mechanical tests indicate a life expectancy of more than 10
Million operations.
Relay Base
Part #30573
8-Pin, for use
with Relay, part number 30225. 115 VAC, 10 AMP rated.
Relay Board
Part #25301
Board relay
LPF-100
Replaceable Felt Tip Pens
Part #25115
Bristol: Blue
Packaged 6 per pack.
Replaceable Felt Tip Pens
Part #25158
Partlow: Green
Packaged 5 per pack.
Replaceable Felt Tip Pens
Part #25135
Honeywell :
Purple (long). Packaged 6 per pack.
Replaceable Felt Tip Pens
Part #25114
Bristol:red
Packaged 6 per pack.
Replacement Felt Tip Pens
Part #25114
Honeywell:red
(short)
Packaged 6 per pack.
Resistor
Part #31125
Resistor, metal
oxide varsitor
Retrofit
Part #45144
Setpoint
retrofit assembly
Rheostat
Part #31289
Rheostat, 100
OHM 25 watt
Set Point Process Temperature Gauge
Part #25165
3-1/2" Dial,
40-240 F range. Standard accuracy style. Special degree
gauges are available upon request.
Note: When ordering a replacement lense, a description is
required. Example: Plastic (or glass), flat (or curved), O-ring
seal, or (seal: none), snap-in type (or screw-on type).
Set Point Process Temperature Gauge Lens
Part #25166
Utilizes the
null-balance principle, which holds the oven or steam cooker
temperature constant. 0-15 PSI. 1/8" NPT
Set Point Timer, 10 hour dial range
Part #30087
Time ranges are
knob adjustable and have a process pointer. The process pointer
is red and displays the remaining time interval. 102-132 VAC, 60
Hz., output rating: 10 Amps at 120 VAC.
Dial Range 10 hrs.
Minimum Setting 20 min.
Dial Divisions 10 min.
Repeat Accuracy +/- 3 min
Set Point Timer, 150 minute dial range
Part #30085
Time ranges are
knob adjustable and have a process pointer. The process pointer
is red and displays the remaining time interval. 102-132 VAC, 60
Hz., output rating: 10 Amps at 120 VAC.
Dial Range 150 min.
Minimum Setting 4.5 min.
Dial Divisions 2 min.
Repeat Accuracy +/- 45 sec.
Set Point Timer, 5 hour dial range
Part #31033
Time ranges are
knob adjustable and have a process pointer. The process pointer
is red and displays the remaining time interval. 102-132 VAC, 60
Hz., output rating: 10 Amps at 120 VAC.
Dial Range 5 hrs.
Minimum Setting 9 min.
Dial Divisions 3 min.
Repeat Accuracy +/- 1.5 sec.
Set Point Timer, 60 minute dial range
Part #30084
Time ranges are
knob adjustable and have a process pointer. The process pointer
is red and displays the remaining time interval. 102-132 VAC, 60
Hz., output rating: 10 Amps at 120 VAC.
Dial Range 60 min.
Minimum Setting 2 min.
Dial Divisions 1 min.
Repeat Accuracy +/- 18 sec.
Shower Miser Timer
Part #31501
Intermittently
turns the cold shower system on or off at timed intervals to
conserve water during the shower cycle.
Shower Miser Timer Base
Part #31502
For use with the
Shower Miser Timer, #31501.
Shower Miser Timer Latch Kit
Part #31503
Latch Kit only
Shower Miser Timer, Panel Mounted
Part #30948
Both "ON" and
"OFF" time intervals are individually adjustable by concentric
knobs on the front of the timer. The combination of "ON" and
"OFF" time is total time cycle of the unit. 102-132 VAC, 50/60
Hz., output rating: 10 Amps at 120 VAC.
Signal Conditioner
Part #31389
API-4003G-I,
4-20 MA
Sock
Part #50048
Wet Bulb
sock,11-1/2" x 4-1/2", Sold 100 per Package
Socket
Part #31144
Relay socket
Socket
Part #31138
Relay socket
Socket
Part #30940
Relay
socket,4PDT
Switch
Part #31247
Switch, key lock
ASD2K10N IDEC
Switch
Part #30892
Switch ASD211N
Temperature Range Transmitters
Part #25148
40-240 F range.
1/2 % accuracy gauges. Note: Special temperature range
transmitters available upon request.
This part is OBSOLETE.
Temperature Range Transmitters
Part #25232
Low temperature
range transmitter. Range 0 - 100 F. This part is OBSOLETE.
Temperature Range Transmitters
Part #25231
Temperature
range transmitter in degrees Centigrade. Range 0 - 150. This
part is OBSOLETE.
Temperature Range Transmitters
Part #25079
40-240 F range.Standard
accuracy gauges. Note: Special temperature range
transmitters available upon request. This part is OBSOLETE.
Terminal Block
Part 31017
Terminal Block
#31017 and terminal connectors #31015 and #31016 are obsolete
and are replaced by part #31609
Terminal Connector
Part #31016
Terminal Block
#31017 and terminal connectors #31015 and #31016 are obsolete
and are replaced by part #31609
Terminal Connector
Part #31015
Terminal Block
#31017 and terminal connectors #31015 and #31016 are obsolete
and are replaced by part #31609
Time Delay Relay
Part #30782
N.C. Relay.
(MCR120A1X1Q-2). A solid state printed circuit board with
mechanical relay used to complete circuit until air flow switch
is energized. 115 VAC, 10 AMP rated.
Note: For use with gas fired equipment only with Barber
Coleman Flame Safe Guard Control.
Timer
Part #31103
Timer, Recycle
ESDR453A3
Transducer, Bellofram
Part #25174
This unit is
supplied by a 4 to 20 ma. signal and converts it to a 3 to 15
PSIG output.
Type J Thermocouple
Part #25151
High temperature
limit located in the return air stream. Same for 0 - 250 or 0 -
400.
Type J Thermocouple Wire
Part #30935
A special wire
(Iron & Constantan) SpecifY length.
Waterproof Cord Connector 1/2
Part #30978
Wet Bulb Socks
Part #50040
Made from 100%
cotton fabric to assure proper evaporation for correct wet bulb
reading. Socks are sewn to properly fit wet bulb diameter giving
you an accurate wet bulb control.
3"x 5-1/2"
For microprocessor control panels on small ovens. 100 per
Package (minimum order). Price is per sock.
Wet Bulb Socks
Part #50044
Made from 100%
cotton fabric to assure proper evaporation for correct wet bulb
reading. Socks are sewn to properly fit wet bulb diameter giving
you an accurate wet bulb control.
5-1/2" x 5-1/2"
For microprocessor control panels on largerl ovens. 100 per
Package (minimum order). Price is per sock.
Wet Bulb Socks
Part #50041
Made from 100%
cotton fabric to assure proper evaporation for correct wet bulb
reading. Socks are sewn to properly fit wet bulb diameter giving
you an accurate wet bulb control.
6"x6"
For pneumatic control panels (programmable-standard, also old
two truck ovens) 3/4" diameter sensor. 100 per Package (minimum
order). Price is per sock.
Wet and Dry Bulb Controller
Part #25002
Two mode
controller which operates on the pneumatic null-balance
principle, controlling the oven or process temperture (Wet Bulb
or Dry Bulb). This part is OBSOLETE.