Motor Control Panel Parts
|
BIC - 10
Part
#30613 |
Used in supply
air stream. (used prior to 1974). Temperature range: 100F. to
600 F. with manual reset.
|
|
Block
Part
#30725 |
Fuse Block,
H25030-2C or F30A2B
|
|
Block
Part
#30727 |
Fuse Block
H25030-3C
|
|
Circuit Breakers
Part
#30667 |
5.0 Amp, 115 V
|
|
Circuit Breakers
Part
#31101 |
Used to protect
control voltage circuit and oven light.
4.5 Amp, 115V
|
|
Contactor
Part
#30976 |
Contactor, MDI
235NO-120A
|
|
Contactor
Part
#30844 |
Contactor, MDI
#360N0-120A 60 amp, 3 pole
|
|
Contactor
Part
#30885 |
Contactor,
CFC3-708 Dura-Kool
|
|
Control Circuit
Part
#30090 |
(Secondary
Voltage Transformer)
Primary Voltage 230/460
VA 500
Secondary Voltage 115
|
|
Control Circuit
Part
#30091 |
(Secondary
Voltage Transformer)
Primary Voltage 230/460
VA 1000
Secondary Voltage 115
|
|
Control Circuit
Part
#30737 |
(Secondary
Voltage Transformer)
Primary Voltage 208
VA 500
Secondary Voltage 115
|
|
Control Switch
Part
#31324 |
Watlow Limit
Switch. This part is obsolete and is replaced by #31645.
|
|
Flame Safeguard Chassis
Part
#31305 |
(Combustion)
Amplifier, flame rod module
|
|
Flame Safeguard Chassis
Part
#31306 |
(Combustion)
UV Amplifier module
|
|
Flame Safeguard Chassis
Part
#31307 |
(Combustion)
Programmable module
|
|
Flame (Combustion) Safeguard Chassis
Part
#31305 |
Provide
automatic ignition and flame safeguard control for gas burners.
Amplifier, flame rod module
|
|
Flame (Combustion) Safeguard Chassis
Part
#30888 |
These are
obsolete and have been replaced by Flame (Combustion) Safeguard
Chassis numbers #31303, #31304, #31305, #31306, and #31307.
Base only for both obsolete flame rod and obsolete UV
scanner types
|
|
Flame (Combustion) Safeguard Chassis
Part
#30887 |
OBSOLETE - flame
rod type
|
|
Flame (Combustion) Safeguard Chassis
Part
#31034 |
OBSOLETE - UV
scanner type. Replaced with items shown below
|
|
Flame (Combustion) Safeguard Chassis
Part
#30888 |
Base (61-3060
Fireye) for Flame Safeguard chassis.
|
|
Flame (Combustion) Safeguard Chassis
Part
#31034 |
This part no.
31034 isobsolete and has been replaced by Flame
(Combustion) Safeguard Chassis numbers #31303, #31304, #31305,
#31306, and #31307. Obsolete, UV scanner type
|
|
Flame (Combustion) Safeguard Chassis
Part
#31303 |
Provide
automatic ignition and flame safeguard control for gas burners.
Chassis
|
|
Flame (Combustion) Safeguard Chassis
Part
#30887 |
This part no.
30887 is obsolete and has been replaced by Flame
(Combustion) Safeguard Chassis numbers #31303, #31304, #31305,
#31306, 30888 and #31307. Obsolete, flame rod type
|
|
Flame (Combustion) Safeguard Chassis
Part
#31304 |
Provide
automatic ignition and flame safeguard control for gas burners.
Programmable module
|
|
Fuse
Part
#31158 |
Panel Fuse
S-8301-5, 5 Pole
|
|
High Temperature Limit Control
Part
#31645 |
Replaces part
#31324
|
|
High Temperature Limit Control
Part
#25150 |
OBSOLETE. See
part #25253
(Return Air Stream)
Limit control in return air steam to protect product from high
temperature (cry bulb only) malfunction. Adjustable from 0 - 250
F. or 0 - 400 F.
|
|
High Temperature Limit Control
Part
#25253 |
Obsolete.
Replaced by part #25238
|
|
High Temperature Limit Switch
Part
#30786 |
The part no.
30786 is an obsolete part.Used in supply air discharge.
Normally set between 350 F. and 550 F. depending on location of
limit switch, size of burner, CFM of main blower (fan). The
control is located on the rotating damper section.
OBSOLETE Part. Replace with parts #31645, #25151, 30896,
31326,31609,31608,30935.
|
|
High Temperature Limit Switch
Part
#31324 |
Watlow Limit
Switch. This part is obsolete and is replaced by #31645.
|
|
High Temperature Limit Switch
Part
#30935 |
Type J Wire
(specify length)
|
|
High Temperature Limit Switch
Part
#25238 |
DC230L-E0-00-10Limit control in return air stream to protect
product from high temperature(dry bulb only) malfunction.
Adjustable from 0-250 F. or 0-400F. Replaces part no. 25253
|
|
High Temperature Limit Switch Tag
Part
#31326 |
Tag
|
|
Ignition Timer (Pilot Cut-Off Timer)
Part
#30082 |
This timer is
set for maximum for 15 seconds. If pilot light is not proven
before this time, system will return to purge cycle (3 minutes).
The reset timer is synchronous driven. This provides an accurate
adjustable time delay between the actuation of the control
circuit and the operation of the load switches. 120/V 50/60 Hz.
NOTE: This timer replaces old type timer No. (HD 32A621)
|
|
Ignition Transformer
Part
#30119 |
Primary voltage:
115V, secondary voltage: 600V. Used to ignite pilot flame of
main burner.
|
|
Latch
Part
#75335 |
Large knob
style, E3-10-505-50
|
|
Mechanism
Part
#31338 |
Square D
mechanism for use on main circuit breaker
|
|
N.O. Relay
Part
#30774 |
MCR 120A1X10-1.
Used for momentary (10 sec.) delay to prevent lock out of air
flow and combustion air circuit. (Used prior 1979)
|
|
Nameplate
Part
#31327 |
Nameplate, Reset
HI Temp Limit Return Air
|
|
Nameplate
Part
#31344 |
Nameplate, High
Temp Limit Alarm
|
|
Plug-In Time Delay Relay - Obsolete.
Part
#30899 |
This part no.
30899 is obsolete. Used for momentary (10 sec.) delay
time to prevent lock out of air flow and combustion air circuit.
120 VAC., 10 Amp rated. This part is replaced with part no.
30082.
|
|
Purge Timer
Part
#30083 |
This timer is
set for minimum 3 minutes for required ventilation of fuel
accumulation during a shutdown period, before lighting or
relighting of oven. This provides an accurate adjustable time
delay between the actuation of control circuit and the operation
of the load switches. 120V, 50/60 Hz. Note: This timer replaces
old type timer No. (HD32A622).
|
|
Push Button
Part
#30896 |
Push Button
|
|
Relay
Part
#30939 |
Relay RY4S-U-AC
120V IDEC
|
|
Relay
Part
#31476 |
Alkar overload
relay used in the motor control panel
|
|
Relay
Part
#30847 |
Relay AE
504-0-0-2
|
|
Relay
Part
#31137 |
Relay, midget
power latching RH2LB120VAC
|
|
Relay Base, SR2P-06
Part
#30573 |
8-Pin, for use
with the AAE-A201 or RR2P-U Relay, #30225. 115 VAC 10 AMP rated.
|
|
Relay, AAE-A201 or RR2P-U
Part
#30225 |
8-Pin, plug-in
style, D.P.D.T. Contact arrangement. 115VAC, 10 AMPS. Mechanical
test indicated a life expectancy of more than 10 million
operations.
|
|
Replacement Neon Light
Part
#30250 |
Replacement neon
light for sequence monitor
125V., .5 Watt.
NOTE: For fuse blocks and fuses, specify No. frame existing
unit.
|
|
Socket
Part
#30940 |
Relay
socket,4PDT
|
|
Socket
Part
#31138 |
Relay socket
|
|
Socket
Part
#31144 |
Relay socket
|
|
Terminal Block
Part
#31609 |
Motor control
panel component, gas heated ovens only.
|
|
Terminal Block
Part
#31017 |
Terminal Block
#31017 and terminal connectors #31015 and #31016 are obsolete
and are replaced by part #31609
|
|
Terminal Block End Cover
Part
#31608 |
Motor control
panel component, gas heated ovens only.
|
|
Terminal Connector
Part
#31015 |
Terminal Block
#31017 and terminal connectors #31015 and #31016 are obsolete
and are replaced by part #31609
|
|
Terminal Connector
Part
#31016 |
Terminal Block
#31017 and terminal connectors #31015 and #31016 are obsolete
and are replaced by part #31609
|
|
Time Delay Relay
Part
#30082 |
Used for
momentary (10 sec.) delay time to prevent lock out of air flow
and combustion air circuit.
|
|
Transformer
Part
#31163 |
Transformer,
heavy-duty #HS1F1.5AS 230/460
|
|
Type J Thermocouple
Part
#25151 |
High temperature
limit located in the return air stream. Same for 0-250 or 0-400
|
|
 |